LC1D115M7
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Taiwan
-
Validity to:
Long-term effective
-
Last update:
2023-08-28 17:50
-
Browse the number:
290
+
- Contactaixin:
yuchichang(Mr.)
- Email: telephone: phone:
-
Arrea:
Taiwan
Address:No.1, Anlin Rd., Yanchao Dist., Kaohsiung City, Taiwan
- Website:
+
Â
Â
Â
LC1D115M7 contactor is designed to effortlessly control a wide range of electrical devices, from small motors to large industrial machines.
Â
Its robust design and premium build quality ensure exceptional performance and durability even in harsh environments.
Â
- Compact Design: allowing seamless integration into your existing electrical systems. Upgrading to the latest technology is now easier than ever, as this contactor eliminates the need for major modifications or costly upgrades.
- Customizability: LC1D115M7 contactor. We understand that each application has unique requirements, and our team of experts will collaborate with you to design a tailored solution. Whether it's voltage rating, current rating, or control circuit, we can create a bespoke contactor that precisely meets your needs.
- User-friendliness: LC1D115M7 features intuitive controls and easily understandable indicators, ensuring ease of use. With its straightforward installation design, integrating it into your existing system is quick and cost-effective.
- Safety: Built-in safety features protect your electrical system from overloads, short circuits, and other hazards. By safeguarding your equipment and minimizing the risk of staff injuries, this contactor prioritizes your well-being.
Â
Â
Â
Range of product |
TeSys D
|
Product or component type
|
Contactor
|
Device short name
|
LC1D
|
Contactor application
|
Motor control
|
Resistive load
|
|
Utilisation category
|
AC-1
|
AC-3
|
|
Poles description
|
3P
|
Power pole contact composition
|
3 NO
|
[Ue] rated operational voltage
|
<= 300 V DC for power circuit
|
<= 1000 V AC 25...400 Hz for power circuit
|
|
[Ie] rated operational current
|
115 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
|
200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
|
|
Motor power kW
|
65 kW at 1000 V AC 50/60 Hz
|
80 kW at 660...690 V AC 50/60 Hz
|
|
75 kW at 500 V AC 50/60 Hz
|
|
59 kW at 415...440 V AC 50/60 Hz
|
|
55 kW at 380...400 V AC 50/60 Hz
|
|
30 kW at 220...230 V AC 50/60 Hz
|
|
Motor power HP (UL / CSA)
|
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
|
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
|
|
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
|
|
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
|
|
Control circuit type |
AC 50/60 Hz
|
Control circuit voltage
|
220 V AC 50/60 Hz
|
Auxiliary contact composition
|
1 NO + 1 NC
|
[Uimp] rated impulse withstand voltage
|
8 kV conforming to IEC 60947
|
Overvoltage category |
III
|
[Ith] conventional free air thermal current
|
200 A at <= 60 °C for power circuit
|
Irms rated making capacity
|
1260 A at 440 V for power circuit conforming to IEC 60947
|
250 A DC for signalling circuit conforming to IEC 60947-5-1
|
|
140 A AC for signalling circuit conforming to IEC 60947-5-1
|
|
Rated breaking capacity
|
1100 A at 440 V for power circuit conforming to IEC 60947
|
[Icw] rated short-time withstand current
|
140 A 100 ms signalling circuit
|
120 A 500 ms signalling circuit
|
|
100 A 1 s signalling circuit
|
|
1100 A <= 40 °C 1 s power circuit
|
|
950 A <= 40 °C 10 s power circuit
|
|
550 A <= 40 °C 1 min power circuit
|
|
250 A <= 40 °C 10 min power circuit
|
|
Associated fuse rating
|
10 A gG for signalling circuit
|
200 A gG at <= 690 V coordination type 2 for power circuit
|
|
250 A gG at <= 690 V coordination type 1 for power circuit
|
|
Average impedance
|
0.60 mOhm at 50 Hz - Ith 200 A for power circuit
|
[Ui] rated insulation voltage
|
1000 V for power circuit conforming to IEC 60947-4-1
|
600 V for signalling circuit certifications UL
|
|
600 V for signalling circuit certifications CSA
|
|
690 V for signalling circuit conforming to IEC 60947-1
|
|
600 V for power circuit certifications UL
|
|
600 V for power circuit certifications CSA
|
|
Electrical durability
|
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
|
0.8 Mcycles 200 A AC-1 at Ue <= 440 V
|
|
Power dissipation per pole
|
7.9 W AC-3
|
24 W AC-1
|
|
Safety cover
|
With
|
Mounting support
|
Plate
|
Rail
|
|
Standards
|
EN 60947-4-1
|
EN 60947-5-1
|
|
IEC 60947-4-1
|
|
IEC 60947-5-1
|
|
UL 508
|
|
CSA C22.2 No 14
|
|
Product certifications
|
BV
|
CCC
|
|
CSA
|
|
DNV
|
|
GL
|
|
GOST
|
|
RINA
|
|
UL
|
|
LROS
|
|
Connections - terminals
|
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: solid - without cable end
|
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: solid - without cable end
|
|
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - with cable end
|
|
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - with cable end
|
|
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - without cable end
|
|
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - without cable end
|
|
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end
|
|
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end
|
|
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end
|
|
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end
|
|
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
|
|
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
|
|
Tightening torque
|
Power circuit: 12 N.m - on connector hexagonal 4 mm
|
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
|
|
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
|
|
Operating time
|
20...50 ms closing
|
6...20 ms opening
|
|
Safety reliability level
|
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
|
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
|
|
Mechanical durability |
8 Mcycles
|
Operating rate
|
2400 cyc/h at <= 60 °C
|
Â
Â
Â
Certificate of Authorized Distributor of Schneider Electrics
Â
Â
UL certificate for Schneider ElectricsÂ
Â
Â
TAF certification for Schneider Electrics
Â
Â
Â
DHL Express
3~7 days delivery
FEDEX Express
3~7 days delivery
AIR Transport
Heavy cargo ship via air with high efficiency.
OCEAN Transport
Heavy cargo ship via sea with competitiive shipping cost.
Â
Â
Â
1
Wire Transfer (T/T)
2
PayPal / Alipay
3
West Union
http://www.tw-rstpower.com/